Quantcast
Channel: PTC Community: Message List - Windchill
Viewing all 8876 articles
Browse latest View live

Re: For a Part, how to set the Default Downstream Location i.e. Folder Location where the Downstream view is to be created

$
0
0

It is controlled by a preference.

 

manufactLocation.jpg

 

If you like, you can also write a delegate that uses a logic for number, location and so on.


Re: For a Part, how to set the Default Downstream Location i.e. Folder Location where the Downstream view is to be created

$
0
0

Hi Binesh,

 

We already tried that preference. This preference sets a fixed location for creation of Downstream parts i.e a folder where downstream parts from all the products will be stored. What we need is that Downstream parts of each product should be stored in the Manufacturing folder of that particular product itself.

 

Regards,

Prasad

Re: For a Part, how to set the Default Downstream Location i.e. Folder Location where the Downstream view is to be created

$
0
0

Hi Prasad, I know it is not easy to set this preference in each of the products. I think writing your own delegate overriding DefaultDownstreamLocationDelegate is the elegant. I wish this is more configurable

OK button doesn't work anymore for Rename action

$
0
0

Hi everybody !

 

Since this morning, when I want to rename a CAD document, the button "OK" doesn't work. I can click but nothing happen, the window doesn't close and the rename is not done.

 

Saturday, an installation of optional components has been done (ProjectLink, MPM Link...) and the problem was not present before.

 

Do you have an idea ?

 

For information:

- Windchill M010-CPS04

- No error in method server logs/apache logs

- Tomcat, InfoEngine caches has been cleared after installation

 

Thank you in advance for your support

 

Florent

use of pentable file?

$
0
0

I just want to know, if I send some drawings to other people for approval, the approver and me all do not use the PENTABLE, then the approver approve the request, the drawings released to FORMAL RERSION

What will be happen ? the dark lines will show up ? if the approver use the PENTABLE ? what will be happen ?  or the dark lines depend on the Windchill ? the Windchill has been set default ?

 

 

 

below is a PDF.


 

 

The outside lines are dark and hard to review, I know I can use and set the “PENTABLE” to make the lines look more thin when I export the drawing to PDF.

But I want to know ,if I do not use the “PENTABLE”, other people release this drawing into “FORMAL” and individuals use a viewer, the “dark lines” will still show up ?

 

 

 

 

I was wondering once we put things into “formal” if the “dark line” would still show up?

Re: use of pentable file?

$
0
0

Okay, the question is how do you generate the PDF? If you are using Windchill to create PDFs, then it doesn't matter what's your pentable configuration is . Windchill uses  CAD worker to generate the PDFs and the settings defined there will be used for the PDF export

issue with drawing.

$
0
0

 

Hello,

 

 

 

Regenerate model and still looks like this below:

 

 

 

 

Once I hit edit for the doors they go together.  Do you know why?

 

 

 

 

 

 

Integration of Windchill Project Link to Microsoft Project Professional 2016

$
0
0

Is Project Link a supported Ad-In of Microsoft Project Professional 2016?


Re: Integration of Windchill Project Link to Microsoft Project Professional 2016

$
0
0

Windchill 11 has a supported version of add-in for MS Project Professional 2016.

Re: OK button doesn't work anymore for Rename action

$
0
0

This sounds like a cached javascript issue. Clear your browser cache, reload the Windchill page and try again.

Re: issue with drawing.

$
0
0

Is this a view of the drawing or an assembly edit window?

 

If it's the drawing you may have to refresh the drawing sheet. There's a config option to not update the drawing views so that the computer isn't wasting time doing that when you are working on the assembly.

Re: OK button doesn't work anymore for Rename action

$
0
0

Unfortunately it is not. I've already tried to clear all the caches but it doesn't work anymore.

 

I checked in developer mode for Internet Explorer, and when I click on OK, I get this:

 

Untitled.png

Collation conversion utility

$
0
0

I have taken a backup from SQL server 2008 R2 and restored it in SQL server 2014. Now the database collation is SQL_Latin1_General_CP1_CS_AS. I have to change the collation to Latin1_General_100_CS_AS_SC. When I run the collation conversion utility, it prompted to enter the details like destination host name, instance name, db admin user name, db user name, default db and application name. When I enter all the details and hit the enter button, the window closed. Nothing happening. Please give me a solution as soon as possible.

Re: Load demo classification files into windchill

$
0
0

Did someone upgraded the classification loadfiles from Counterpart in 10.1?

Like loaded the examples into 10.1 and upgraded to 10.2 or 11?

Please share these files

The old counterpart example was much more complete than the three nodes today.

Thanks

Re: Load demo classification files into windchill


Re: Collation conversion utility

$
0
0

Try to start AlterDatabaseCollation.cmd in Command Prompt.

Re: Collation conversion utility

$
0
0

Thanks for your reply. I have already tried that. The same thing happened. Please let me know if you know some other details.

Re: Collation conversion utility

$
0
0

Do you have a log file generated in scudirectory\collation_conversion\logs? If yes, please share that

Select specific Java JRE?

$
0
0

Hi,

 

is there an option to set a specific JRE for Creo, Windchill, ...

 

We are limited to Java 7 because of Windchill 10.2. So I'd like to install Java 7 in a seperate Folder and use it only for Creo.

We are using the mozilla based browser.

 

br Bernhard

Re: Collation conversion utility

$
0
0

No Binesh. The conversion process didn't even started. Hence, No logs generated. The folder is empty only.

Viewing all 8876 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>