Re: For a Part, how to set the Default Downstream Location i.e. Folder Location where the Downstream view is to be created
Re: For a Part, how to set the Default Downstream Location i.e. Folder Location where the Downstream view is to be created
Hi Binesh,
We already tried that preference. This preference sets a fixed location for creation of Downstream parts i.e a folder where downstream parts from all the products will be stored. What we need is that Downstream parts of each product should be stored in the Manufacturing folder of that particular product itself.
Regards,
Prasad
Re: For a Part, how to set the Default Downstream Location i.e. Folder Location where the Downstream view is to be created
Hi Prasad, I know it is not easy to set this preference in each of the products. I think writing your own delegate overriding DefaultDownstreamLocationDelegate is the elegant. I wish this is more configurable
OK button doesn't work anymore for Rename action
Hi everybody !
Since this morning, when I want to rename a CAD document, the button "OK" doesn't work. I can click but nothing happen, the window doesn't close and the rename is not done.
Saturday, an installation of optional components has been done (ProjectLink, MPM Link...) and the problem was not present before.
Do you have an idea ?
For information:
- Windchill M010-CPS04
- No error in method server logs/apache logs
- Tomcat, InfoEngine caches has been cleared after installation
Thank you in advance for your support
Florent
use of pentable file?
I just want to know, if I send some drawings to other people for approval, the approver and me all do not use the PENTABLE, then the approver approve the request, the drawings released to FORMAL RERSION
What will be happen ? the dark lines will show up ? if the approver use the PENTABLE ? what will be happen ? or the dark lines depend on the Windchill ? the Windchill has been set default ?
below is a PDF.
The outside lines are dark and hard to review, I know I can use and set the “PENTABLE” to make the lines look more thin when I export the drawing to PDF.
But I want to know ,if I do not use the “PENTABLE”, other people release this drawing into “FORMAL” and individuals use a viewer, the “dark lines” will still show up ?
I was wondering once we put things into “formal” if the “dark line” would still show up?
Re: use of pentable file?
Okay, the question is how do you generate the PDF? If you are using Windchill to create PDFs, then it doesn't matter what's your pentable configuration is . Windchill uses CAD worker to generate the PDFs and the settings defined there will be used for the PDF export
issue with drawing.
Integration of Windchill Project Link to Microsoft Project Professional 2016
Is Project Link a supported Ad-In of Microsoft Project Professional 2016?
Re: Integration of Windchill Project Link to Microsoft Project Professional 2016
Windchill 11 has a supported version of add-in for MS Project Professional 2016.
Re: OK button doesn't work anymore for Rename action
This sounds like a cached javascript issue. Clear your browser cache, reload the Windchill page and try again.
Re: issue with drawing.
Is this a view of the drawing or an assembly edit window?
If it's the drawing you may have to refresh the drawing sheet. There's a config option to not update the drawing views so that the computer isn't wasting time doing that when you are working on the assembly.
Re: OK button doesn't work anymore for Rename action
Collation conversion utility
I have taken a backup from SQL server 2008 R2 and restored it in SQL server 2014. Now the database collation is SQL_Latin1_General_CP1_CS_AS. I have to change the collation to Latin1_General_100_CS_AS_SC. When I run the collation conversion utility, it prompted to enter the details like destination host name, instance name, db admin user name, db user name, default db and application name. When I enter all the details and hit the enter button, the window closed. Nothing happening. Please give me a solution as soon as possible.
Re: Load demo classification files into windchill
Did someone upgraded the classification loadfiles from Counterpart in 10.1?
Like loaded the examples into 10.1 and upgraded to 10.2 or 11?
Please share these files
The old counterpart example was much more complete than the three nodes today.
Thanks
Re: Load demo classification files into windchill
For Windchill 11.0 M020
Re: Collation conversion utility
Try to start AlterDatabaseCollation.cmd in Command Prompt.
Re: Collation conversion utility
Thanks for your reply. I have already tried that. The same thing happened. Please let me know if you know some other details.
Re: Collation conversion utility
Do you have a log file generated in scudirectory\collation_conversion\logs? If yes, please share that
Select specific Java JRE?
Hi,
is there an option to set a specific JRE for Creo, Windchill, ...
We are limited to Java 7 because of Windchill 10.2. So I'd like to install Java 7 in a seperate Folder and use it only for Creo.
We are using the mozilla based browser.
br Bernhard
Re: Collation conversion utility
No Binesh. The conversion process didn't even started. Hence, No logs generated. The folder is empty only.