Re: How to call Windchill API from outside the Windchill
if your Java code is on same server as Windchill, following will help you. https://support.ptc.com/appserver/cs/view/solution.jsp?n=CS18364
View ArticleRe: How to call Windchill API from outside the Windchill
And if you want to go IE task approach, use attached IE task 1. In IE task FileUpload.xml, replace "GOLF_CART" container name with product name where this file needs to be uploaded. Or you can...
View ArticleRe: Is there still a Product Structure Explorer in Windchill 10.2
Looks like the slide got messed up from the original in the PDF conversion To your question on UOM - as you might now this has always been this way, its not new. The reason it is supported is that...
View ArticleRe: Is there any way to send a real time message to Windchill users via the...
Hi Barry, There have been a lot of good ideas mentioned here, but the recommended way is to use the header to send mass messages. Here is an article that covers...
View ArticleRe: SPR 2207900 – complain to PTC for BIG regression on Windchill 10.2
Hello Marco, A favorable response has been given to the consultant. Your issue should be resolved. I thank you for bringing this to PTC attention Jean-Claude Niyonkuru
View ArticleRe: How to detect domain in OIR?
Hi Patrick, There is some documentation regarding OIRs that support basic logic and custom algorithms....
View ArticleRe: WBM Error Revise transitions not defined for latest version in life cycle...
Jennifer, I also ran into this, and solved following these steps. identify which lifecycle are being used by WTDocumentsEdit the lifecycle and select each stateFor each state set the transition called...
View ArticleRe: PDF publish outside of Windchill PDMLink
Hi Kevin, Did you manage to publish the pdf's outside Windchill? I am trying to do the same thing. Hope you have the aswer to it? Maybe you could share it wirh me. Thanks in advance! Kind regards,Michiel
View ArticleRe: How to call Windchill API from outside the Windchill
Thank you Yogesh, This will help me.
View ArticleRe: Which Rehosting Method?
Brian, I'm also on 10.2 M020 in a virtual environment. I have a .bat file that manually stops the services on the test system, copies the files from production, then runs the rehosting utility. It...
View ArticleRe: Windchill desktop integration basic settings/configuration
Hi Milan -- Yes! You can set this using the preference manager utility in Windchill: From Windchill, go to Quick Links > My Settings > Preferences The preference is available under Documents....
View ArticleHow to Connect Multiple Cad Appliations to Workgroup Manager?
I have a user that needs to connect workgroup manager to AutoCAD Mech. and also AutoCAD Elect. Currently he registers to one application and then changes to the other each time he uses the...
View ArticleRe: How to Connect Multiple Cad Appliations to Workgroup Manager?
I just noticed this Document - CS19175 looks like the only way to change applications is to unregister one and then register the other. Shows not plans to fix in 9.1 and 10.0 anyone tried with newer...
View ArticleRe: how is the calculated weight actually calculated in the aggregated...
Goran, is this something that you are calculating with Creo or Windchill?
View ArticleRe: How to solve this problem: dbg_err_crash() - continuing from serious...
Anthony, does this happen with a new workspace cache? For all models downloaded/checked in? My guess is that he may be connecting CEP to the old Creo 3.0 cache and that could be causing problems. If...
View ArticleRe: How to get the group names of the user who has logged in .Need to achieve...
Anuradha, were you able to get what you needed? it seems like the basics were given here, but some further customization of the code may be required to work in your specific environment. Please let us...
View ArticleRe: Report for Promotion Request that have been approved....
Bryant, was Marco's extensive and excellent document helpful for you?
View ArticleRe: Restore Part Autonumbering
Walter, Attached is the OOTB WTPart OIR with autonumbering enabled. You will want to pay particular attention to these sections: <!-- set the number to a generated number -->...
View ArticleUnable to start Windchill Method Server During Cloning Process
Dear All, Good Day To You...I'm performing Windchill cloning process. As part of that, performed below activities on Source machine.. Installed Windchill 9.1 M070 along with SQL Server 2005 Standard...
View ArticleRe: Which Rehosting Method?
Thanks for this information I am trying to do the same thing.FYI:I noticed that you had stop and start windchill services as well as clearing the tomcat cache as manual steps. I just wrote some...
View Article