Quantcast
Channel: PTC Community: Message List - Windchill
Viewing all 8876 articles
Browse latest View live

Selecting to open viewable in Creo View - from workspace

$
0
0

For only some users, for a CAD Doc in a workspace or in commonspace, selecting the viewable image from within the browser inside CAD (either Creo Parametric or SolidWorks WGM) results in nothing.  Actions, Open in, Creo View is grayed out.  For other users, this works perfectly.

 

No help from tech support on what may be causing this difference.

 

Ideas?

thanks

 

shown below is on my machine which works - for others, no effect from selecting the image and Open in Creo View is grayed out.

 


Re: Selecting to open viewable in Creo View - from workspace

Re: Where are the thumbnails of the objects (Business Objects) are stored ? On Master/Replica/BLOB ?

$
0
0

What version of Windchill ?

What thumbnails?

  • The thumbnail navigator?
  • The Details tab?

 

I have a similar issue with Windchill 11.0 M020 and the new WebGL thumbnail viewer. My issue is the (3d) thumbnails don't show on the Details tab when user has their vaulting preference set to a replica site. This is only an issue with 3d thumbnails on the Details tab. The thumbnail navigator works fine. 2d thumbnails work fine in the Details tab. This issue is reproducible with FireFox, Chrome, and IE

FireFox 45.8.0 ESR

Chrome 57.0.2987.133 (64-bit)

IE 11

 

This was not a problem with Windchill 11.0 M010 when thumbnails were viewed with the Creo View plugin.

 

I have a call open with PTC on this issue however no solution yet.

Re: Selecting to open viewable in Creo View - from workspace

$
0
0

What release and build of Windchill?

What release and build of Creo Parametric?

Do all the users have the same release and build of Creo Parametric?

Re: Selecting to open viewable in Creo View - from workspace

$
0
0

What release and build of Windchill? 10.2 M030 CPS 14

What release and build of Creo Parametric? 3.0 M060 (2/3 of users); M110 (1/3 of users, soon to be all)

Do all the users have the same release and build of Creo Parametric?

Affects at least one each of users on both M060 and M110.

Re: Selecting to open viewable in Creo View - from workspace

$
0
0

Well then you don't have the issue of needing at least Creo Parametric 3.0 M100 for Windchill 11.0 M010 and its new pvagent.exe process like I had.

I would try the following

  • switching the config.pro option windows_browser_type on the affected users and see if that does anything
  • removing the local workspace cache and re-registering the Windchill server

You didn't say what version of Creo View these users had. Might try updating to the latest supported by Windchill 10.2 M030 cps14. (Creo View 4.0 maybe??)

Re: Selecting to open viewable in Creo View - from workspace

$
0
0

aaaaaaaaaaaaaaaaahhhhhhhhhhhhhh  - it's because I'm on chromium_browser and I've set it for a few users.  That's it.  We're going to switch everyone over.

 

thanks

Re: Selecting to open viewable in Creo View - from workspace

$
0
0

I am running everybody with chromium_browser. However there are a couple of things to keep in mind. If Creo Parametric crashes (of course this never happens...) the creoagent.exe process and related zbcefr.exe processes will be left running. Quite frequently this leads to embedded browser issues sometime during the life of the next session of Creo Parametric that is fired up.

 

Your affected users that are running IE might not have the ugly Microsoft hack "Display intranet sites in Compatibility View" turned off:

https://support.ptc.com/appserver/cs/view/solution.jsp?n=CS203757


What are the changes in WBM 11 M020 configuration?

$
0
0

I am trying to configure WBM 11 M020, but it asks the staging database instance URL in it.Which conflicts with the staging database identity in later stages.

java.lang.SecurityException: Access denied

$
0
0

Hello,

 

Having some issues with Windchill Log files being generated repeatedly every minute.

 

I have a call into PTC but they have not responded with anything that resolved the issue?

 

Would you have any suggestions?

 

===========================================================================================

 

2017-04-03 09:40:49,625 INFO  [main] wt.server.manager.startup - Creating wt.manager.jmx.Startup

 

2017-04-03 09:40:49,625 INFO  [BackgroundMethodServerMonitor] wt.server.manager.startup - Starting 1 BackgroundMethodServer instance

 

2017-04-03 09:40:49,625 INFO  [MethodServerMonitor] wt.server.manager.startup - Starting 3 MethodServer instances

 

2017-04-03 09:40:49,640 ERROR [RMI TCP Connection(3)-10.3.50.172] wt.cache.server.wt.cache.MasterCacheMonitor - caught cache server call exception

 

java.rmi.RemoteException: Unable to register slave cache; nested exception is:

 

java.lang.SecurityException: Access denied

 

at wt.cache.RemoteCacheServer.registerSlaveInternal(RemoteCacheServer.java:251)

 

at wt.cache.RemoteCacheServer$1.call(RemoteCacheServer.java:183)

 

at wt.cache.RemoteCacheServer$1.call(RemoteCacheServer.java:178)

 

at wt.cache.RemoteCacheServer.callTimeAndLogRemoteCallableLow(RemoteCacheServer.java:714)

 

at wt.cache.RemoteCacheServer.callTimeAndLogRemoteCallable(RemoteCacheServer.java:687)

 

at wt.cache.RemoteCacheServer.registerSlave(RemoteCacheServer.java:176)

 

at wt.cache.CacheManager.<init>(CacheManager.java:599)

 

at wt.cache.MasterCacheMonitor.<init>(MasterCacheMonitor.java:97)

 

at sun.reflect.NativeConstructorAccessorImpl.newInstance0(Native Method)

 

at sun.reflect.NativeConstructorAccessorImpl.newInstance(NativeConstructorAccessorImpl.java:57)

 

at sun.reflect.DelegatingConstructorAccessorImpl.newInstance(DelegatingConstructorAccessorImpl.java:45)

 

at java.lang.reflect.Constructor.newInstance(Constructor.java:526)

 

2017-04-03 09:40:51,200 INFO  [wt.jmx.core.SharedScheduledExecutor.worker] wt.summary.general - JVMName=7148@AME-CRE-PRD01, HeapMemoryUsage=396462624, NonHeapMemoryUsage=26971560, Uptime=5380, ProcessCpuTime=4258827300, JITCTime=1428, GarbageCollectors=[PS MarkSweep,PS Scavenge], GCTime=[0,0], GCCount=[0,0], Classes=3901, Threads=31, TotalStartedThreadCount=33, PermGenPercentCollUsage=0.0, PermGenPercentUsage=29.844153799661775, CodeCachePercentUsage=2.6195526123046875, SystemLoadAverage=-1.0

 

2017-04-03 09:40:52,930 ERROR [RMI Unreferenced-1] wt.cache.server.com.ptc.core.lwc.server.cache.ConstraintRuleCache - caught cache server call exception

java.rmi.RemoteException: Unable to register slave cache; nested exception is:

 

java.lang.SecurityException: Access denied

 

at wt.cache.RemoteCacheServer.registerSlaveInternal(RemoteCacheServer.java:251)

 

at wt.cache.RemoteCacheServer$1.call(RemoteCacheServer.java:183)

 

at wt.cache.RemoteCacheServer$1.call(RemoteCacheServer.java:178)

 

at wt.cache.RemoteCacheServer.callTimeAndLogRemoteCallableLow(RemoteCacheServer.java:714)

 

at wt.cache.RemoteCacheServer.callTimeAndLogRemoteCallable(RemoteCacheServer.java:687)

 

at wt.cache.RemoteCacheServer.registerSlave(RemoteCacheServer.java:176)

 

at wt.cache.CacheManager.reset(CacheManager.java:864)

 

at wt.cache.CacheManager.ok(CacheManager.java:482)

 

at wt.cache.CacheManager.unreferenced(CacheManager.java:1402)

 

at sun.rmi.transport.Target$1.run(Target.java:329)

 

at java.lang.Thread.run(Thread.java:745)

 

Caused by: java.lang.SecurityException: Access denied

 

at wt.cache.CacheManager.checkAccess(CacheManager.java:1335)

 

at wt.cache.CacheManager.registerSlave(CacheManager.java:1147)

 

at sun.reflect.GeneratedMethodAccessor58.invoke(Unknown Source)

 

at sun.reflect.DelegatingMethodAccessorImpl.invoke(DelegatingMethodAccessorImpl.java:43)

 

at java.lang.reflect.Method.invoke(Method.java:606)

 

at sun.rmi.server.UnicastServerRef.dispatch(UnicastServerRef.java:322)

 

at sun.rmi.transport.Transport$1.run(Transport.java:177)

 

at sun.rmi.transport.Transport$1.run(Transport.java:174)

 

at java.security.AccessController.doPrivileged(Native Method)

 

at sun.rmi.transport.Transport.serviceCall(Transport.java:173)

 

at sun.rmi.transport.tcp.TCPTransport.handleMessages(TCPTransport.java:556)

 

at sun.rmi.transport.tcp.TCPTransport$ConnectionHandler.run0(TCPTransport.java:811)

 

at sun.rmi.transport.tcp.TCPTransport$ConnectionHandler.run(TCPTransport.java:670)

 

at java.util.concurrent.ThreadPoolExecutor.runWorker(ThreadPoolExecutor.java:1145)

 

at java.util.concurrent.ThreadPoolExecutor$Worker.run(ThreadPoolExecutor.java:615)

 

at java.lang.Thread.run(Thread.java:745)

 

at sun.rmi.transport.StreamRemoteCall.exceptionReceivedFromServer(StreamRemoteCall.java:275)

 

at sun.rmi.transport.StreamRemoteCall.executeCall(StreamRemoteCall.java:252)

 

at sun.rmi.server.UnicastRef.invoke(UnicastRef.java:161)

 

at wt.cache.CacheManager_Stub.registerSlave(Unknown Source)

 

at wt.cache.RemoteCacheServer.registerSlaveInternal(RemoteCacheServer.java:205)

 

... 10 more

 

 

 

Thanks in advance,

DTI: Measurement unit of a mapped attribute not displayed correctly

$
0
0

Hi,

 

we are using DTI and mapping attributes from PDMLink to Word or Excel.

 

One of the attributes is a Temperature and measurement unit is defined in "Celsius".

The attribute value and the corresponding measurement unit is displayed correctly in PDMLink.

 

However, when mapping the attribute to Word document, then the value is converted into Kelvin and the measurement unit is shown as "K".

 

According to PTC support this seems to be spec, and they asked me to create a product idea.

 

How can I create the product idea?

User would never accept the temperature in Kelvin and therefore I need to apply a workaround for this, but on the other side I want PDMLink to improve.

 

Kind regards.

Tom

dual revision scheme

$
0
0

What would be the best procedure for switching revisions schemes between a development phase and a production phase? Our development phase would be alpha characters and at production would switch to numeric.

Is anyone using Windchill to manage a software product that does not have CAD?

$
0
0

We are actually a chemical company, but it occurred to me that some practices for managing a software type product might apply to us (in part) rather than a typical manufacturing environment. Actually there are two things that could be managed: The architectural/electrical construction drawings for building the process buildings and equipment for making the chemicals (not mass produced) and the actual chemicals themselves that are mass produced.

Any suggestions?

Re: dual revision scheme

Re: dual revision scheme

$
0
0

Jeff, that's exactly what my company does too.   Tom Uminn has excellent advice,  that would be a good place to start.


Re: dual revision scheme

$
0
0

We are set up to that today. Alpha are released to a Pre-Production state and numeric revisions are Released state. All controlled by Windchill and the promotion process and Revise.

Re: Is anyone using Windchill to manage a software product that does not have CAD?

$
0
0

The architectural drawings would be a type of CAD file, so a perfect fit for Windchill.

The chemical processes could also be managed, maybe like some of the consumer good companies use Windchill. I know there are clothing manufacturers who use Windchill and Proctor & Gamble uses it for packaging.

Re: WINDCHILL HOW REAL NUMBER ATTRIBUTE VALUE DISPLAY 3 DIGIT AFTER DECIMAL PLACES..??

$
0
0

Officially, according to https://support.ptc.com/appserver/cs/view/solution.jsp?n=CS36590 there is no configuration point for this.

You can vote for the idea in https://www.ptcusercommunity.com/ideas/6198 to push the realization.

 

On the other hand, LoadFromFile *.xml files and csv files have the number of significant digits supplied with the load for every real figure:

csv: csvvalue2 https://support.ptc.com/appserver/cs/view/solution.jsp?n=CS232145

xml: myValue|precision https://support.ptc.com/appserver/cs/view/solution.jsp?n=CS40610

 

like:

<csvvalue>DATA| com.ptc.core.meta.common.FloatingPoint|23.42|4</csvvalue>

<csvvalue>DATA| com.ptc.core.meta.common.FloatingPoint|23.4200|6</csvvalue>

<csvvalue>DATA| com.ptc.core.meta.common.FloatingPoint|1.990|4</csvvalue>

 

 

 

so if you can import the values through xml, you could specify the number of significant digits editing the precision string.

Re: dual revision scheme

$
0
0

Take a look at this picture:

By the way, Mike Lockwood was the one who helped us set this up originally.

Re: What is Change Promotion utility and what are new things in Windchill 11 wrt Change Promotion Utility ?

$
0
0

This utility in Windchill 11.0 F000 “Business Administrative Change Promotion Utility” provides a way to move administrative changes made in a pre-production PTC Windchill installation to a production PTC Windchill.

For example, a policy access control rule can be created in a test system to ensure that the policy rule functions as intended. After testing is complete, the change can be moved to the production PTC Windchill system using the business administrative change promotion command-line utility.

 

If user has made some modification in access control rule on source server and would like to propagate the same changes on Production Server. In this case the user don’t have to redo the same modification manually on production Server, they can use the “Business Administrative Change Promotion Utility”.

 

The Business Administrative Change Promotion is a command line utility which has the –export and –import parameter which is use to export the policy rule from Source system and import it Target system.

 

We can refer to these links of Windchill Help Center to get the brief details about how this utility work: 

Viewing all 8876 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>