I am working on the latest Enovia V6 2013 version with Creo2 parametric. The install uses third party CAD integration tool (previoulsy known as MxPro). I have been told that our Enovia install has...
View ArticleRe: New WTPart Creation
We've been using Windchill for 7+ years now. 200,000 CAD Document Numbers Created Product Stucture via "backfill" en masse starting about 3 1/2 years ago. Lots of complexity to it but can be done....
View ArticleFile does not exist
I have a user who tries to open up a solidworks model from Workgroup manager and he gets an error saying the part does not exist. I can open the file myself, so the file is there and not corrupt. He...
View ArticleRe: Additional attributes required in suggest text box search under change...
Hi , For this functionality to bring in State details in the suggestions displayed you need to customise the PartMasterPickerSuggestable class that implements Suggestable.Basically the suggestion work...
View ArticleRe: New WTPart Creation
Mike, if I remember since 9.1 ... or may be M060, there's no need anymore to have modifiy permission on CADDocuments to associate them to WTparts. Links are owned by WTparts. Shaun There's Out of...
View ArticleRe: New WTPart Creation
I guess when you write "document" you mean "CAD Document". Isn't it? Any way... I am quite sure there is a command utility to create via batch WTPart from existing CAD Document. It is used (as option)...
View ArticleCustomizing commonSchedule Queue to add a custom job
Hi all, I have a requirement where in I want to execute a java class as a job. I want to add my custom job to the 'commonScheduleQueue' available under 'Queue Management' in Utilities. Does any one...
View ArticleRe: Problems with Configuration of Windchill Desktop Integrations (DTI)
figured it out. Had to enter it like this: http://wcdevj.mycompany.com/Windchill/
View ArticleRe: File does not exist
Do you have any remote file servers? It could be that the file is corrupt/missing on one site, but present on another. If this user's preferred site is set to the site where the file is corrupt and...
View ArticleRe: Mini Thumbnails - XML source content does not appear
Hi Kathleen, If you take a look at the DerivedImage using the listcontent.jsp (See CS70251) do you see a thumbnail image listed as part of the contents for the representations not displaying...
View ArticleRe: New WTPart Creation
Vittorio, I believe you are referring to the Windchill Part Creation Utility. And the preference is Windchill Workgroup Manager > Server > Auto Associate > Set Revision For Part in 9.1.
View ArticleRe: Config file problems
Are you getting prompted to log in upon start up when the config.pro options are pointing to Windchill? Is there a possibility that the log in window is popping up behind the screen, thus giving the...
View ArticleRe: What is your best practice for handling step files?
https://www.ptc.com/appserver/cs/view/solution.jsp?n=CS79209The STEP files need to be stored as WTDocuments and then you can configure/use a STEP worker
View ArticleRe: Logical Attributes or Alias Attributes
The syntax for alias attributes is different than for logical attributes. Take a look at https://www.ptc.com/appserver/cs/view/solution.jsp?n=CS131355 and the Alias Attribute Mapping help topic...
View ArticleRe: windchill autonumber and "save as" in creo incompatible?
I don't think there is a way around this since the rename_drawings_with_object stipulates that the drawing name must be the same as the model name in order for the drawing to get renamed with the model...
View ArticleRe: How to edit the Display Name and description of a document type in 9.1 ?
You may need to restart the server after manually updating the db table in order to see the change
View ArticleRe: Change object templates import/export
Thanks for that Lori Lee Sood. I have Windchill 10.0
View ArticleRe: New WTPart Creation
Yes Lori, exactly what I meant.I am not sure if the preference has any relatioships (can drive wtpart revision in part creation utility).
View ArticleWindchill Workgroup Manager 10.1 M040 Functional Patch?
Hello, we run wc 10.1 M040 and are impacted by the bug that causes intermittent connectivity with the wc server. the problem and solution is documented in CS133804 It appears you need to make a request...
View ArticleRe: PLM Windchill is not opening in creo2.0
Hello,That comes from the version of IE installed, who is not supported.See software matrice Best regardsPascal