Error while creating a part when Security Labels are configured

$
0
0

Hi,

 

I had configured Security Labels in my system. The method server is ready whenever i start and it doesn't crash. However few errors are being shown. PFB text of those errors.

 

ERROR [main] wt.access.configuration.SecurityLabelsHandler  - The UFID 'cn=Agreement Managers,ou=people,cn=AdministrativeLdap,cn=Windchill_10.2,o=xyz|Ldap.corp.xyz.com|Ldap.corp.xyz.com' is invalid.

ERROR [main] wt.access.configuration.SecurityLabelsHandler  - The UFID 'cn=US Persons,cn=Public,ou=people,cn=AdministrativeLdap,cn=Windchill_10.2,o=xyz|Ldap.corp.xyz.com|Ldap.corp.xyz.com' is invalid.

ERROR [main] wt.access.configuration.SecurityLabelsHandler  - The UFID 'cn=US Persons,cn=Public,ou=people,cn=AdministrativeLdap,cn=Windchill_10.2,o=xyz|Ldap.corp.xyz.com|Ldap.corp.xyz.com' is invalid.

ERROR [main] wt.access.configuration.SecurityLabelsHandler  - The UFID 'cn=US Persons,cn=Public,ou=people,cn=AdministrativeLdap,cn=Windchill_10.2,o=xyz|Ldap.corp.xyz.com|Ldap.corp.xyz.com' is invalid.

ERROR [main] wt.access.configuration.SecurityLabelsHandler  - There are non-fatal syntax errors in the security labels configuration file. 

Please refer to the Method Server log file for details.

.

.

.

.

.

ERROR [main] wt.access.agreement.StandardAgreementService  - configureAgreementService: The group defining the agreement managers was not set properly in the Security Labels configuration file.  This has the effect disabling the agreements UI and prevents write access to agreements for all users, including administrators.  Existing agreements will still be evaluated during access checks.

 

and then the method server gets ready.

 

However when i navigate to a Product and then create a part i am able to create the part successfully but i am not able to view the part created in the product folders. An error is being reported in the Method Server Log like

 

ERROR [ajp-bio-8010-exec-1] wt.access.evaluation.report wcadmin - "Administrator" does not have Read permission for "Part - 0000000003, ABC, A.1 (Design)" in Administrative Domain "Site, Organization - Demo Organization, Product - GOLF_CART /Default".

ERROR [ajp-bio-8010-exec-1] com.ptc.mvc.controllers.ExceptionController wcadmin - message : You do not have access to this object or it does not exist.

error:-------------javax.servlet.ServletException: wt.util.WTException: You do not have access to this object or it does not exist.

javax.servlet.ServletException: wt.util.WTException: You do not have access to this object or it does not exist.

.

.

.

.

Caused by: wt.util.WTException: You do not have access to this object or it does not exist.

  at com.ptc.windchill.enterprise.navigation.RedirectUtility.redirectToNewAction(RedirectUtility.java:240)

  at com.ptc.windchill.enterprise.navigation.RedirectUtility.redirectToNewAction(RedirectUtility.java:171)

  at com.ptc.jca.mvc.components.TypeBasedRedirector.handleGetContextObjectException(TypeBasedRedirector.java:86)

  ... 39 more

ERROR [ajp-bio-8010-exec-1] wt.servlet.ServletRequestMonitor.request wcadmin - 2017-02-17 16:22:03.992 +0530, 2uuz52;iz9owcyi;7852;uxo3jz;2039, wcadmin, 10.76.51.102, /Windchill/ptc1/tcomp/infoPage, oid=VR%3Awt.part.WTPart%3A138806&portlet=component, POST, 501, 0.0624004, 0.097618893

ERROR [ajp-bio-8010-exec-1] wt.access.evaluation.report wcadmin- "Administrator" does not have Read permission for "Part - 0000000003, ABC, A.1 (Design)" in Administrative Domain "Site, Organization - Demo Organization, Product - GOLF_CART /Default".

ERROR [ajp-bio-8010-exec-1] com.ptc.mvc.controllers.ExceptionController wcadmin - message : ATTENTION:  Secured Action. You do not have the necessary authorization for this operation. Contact your administrator if you believe you have received this message in error.

error:-------------wt.util.WTRuntimeException: ATTENTION:  Secured Action. You do not have the necessary authorization for this operation. Contact your administrator if you believe you have received this message in error.

 

All these operations were performed in Site itself. Can you please let me know how to debug this error.

 

Thanks and Regards,

Aditya Achanta


How to create an Agreement

$
0
0

Hi.

 

Within Security Labels Configuration file I included a tag for Agreement Configuration.

 

AgreementConfiguration enabled="true">

    <AgreementManagersGroup>

        <groupUfid>cn=Agreement Managers,ou=people,cn=AdministrativeLdap,cn=Windchill_10.2,o=xyz|Ldap.corp.xyz.com|Ldap.corp.xyz.com</groupUfid>

    </AgreementManagersGroup>

 

I then created a group called as Agreement Managers in Site Utilities and then added a user to that group.

 

However when i login with that user i am not able to find any icon to create a new agreement ? Can you please let me know if my process is right ? If not can you please let me know how to create the same ?

 

Thanks and Regards,

Aditya Achanta

Re: How can I get the OOTB ACLs?

Re: How to create an Agreement

$
0
0

Hi Aditya,

 

You should see Agreements in the product container, the link takes you to the Agreement Folder, and that's where you find the New Agreement button. so A policy is also needed for the user to be allowed to create that type, or just put him in the product manager group to test.

 

2017-02-17_135323.bmp

 

2017-02-17_140137.bmp

 

Regards

Rob

Re: Filter End item (and related parts) from Promotion request collection

$
0
0

Select ' END ITEM 1' in table

Select 'Collect Objects' from table options

Change dependency to 'None'

 

You can automatically collect all parts below in structure or no related parts by structure.

If you want anything in between you have to explicitly add parts to promotion, or over collect and remove parts from table.

 

If parts below below in structure are already at the promotion target state it does no harm to leave them in the promotion. They will be in the promotion baseline, but just to come along for the ride.

 

Within promotions > collector section of preferences you can edit the default collection rule for promotion to best suit your need.

Re: Converting WT file as End Item WT

$
0
0

What do you mean by 'marked as a primary end item'?

Re: Converting WT file as End Item WT

$
0
0

End item are parts in a product that are finally assembled or sold to a customer. When you create parts with end item attribute as yes, windchill assigns it as primary end item for the context. Primary end items get automatically collected to your changes.You can find it from the details page of the product and unset them.

 

unset-end item.jpg

 

Apart from above, you should also remove the end item from any changes to be able to edit the end item attribute. Navigate to the changes tab of the part, look if there are any  change objects to which it is associated, if yes, edit the affected end items table to remove it.

 

changeend.jpg

Re: How to create a custom Business rule

$
0
0

Keir,

 

I am having the same challenge.

Have you ever found out how to add new business rules?


Re: How to create an Agreement

$
0
0

HI Rob,

 

Thank you. I had created an agreement. However it is in Inactive state.

 

How to make it active ? Can you please let me know about it ?

 

Thanks and Regards,

Aditya Achanta

Re: Error while creating a part when Security Labels are configured

$
0
0

Hi All,

 

If anyone is aware of how to resolve this error kindly let me know about the same.

 

Thanks and Regards,

Aditya Achanta

Re: Windchill with docker ?

$
0
0

hi,

 

I just wish i know how to do it. Is there even a way to install Windchill using terminal only?

 

~J

Re: How to create an Agreement

$
0
0

Hi, if the user has the right access, they can set state.

 

2017-02-20_092135.bmp

 

Regards

Rob

Re: How to create an Agreement

$
0
0

Hi Rob,

 

Thanks for your quick response.

 

Thank you.

 

Best Regards,

Aditya Achanta

Need some inputs on testing(both Manual and Automation) for Windchill

$
0
0

Hi All,

 

I have just got a scenario like if there is huge amount of data got migrated from a Non Windchill system or from a legacy Windchill system to Windchill 10.2 M030.

 

If huge amounts of data got migrated or loaded into the target system how are we going to check if the data got migrated or loaded properly ? Is it through manual testing or an automated testing or is there any other way to check the data ?

 

If there are any tools regarding the same can you please let me know like which tool is used and how do we use the same ?

 

Thanks and Regards,

Aditya Achanta

Recovery of the accidentally deleted workspace from wind-chill

$
0
0

Is there any possible way to recover an accidentally deleted workspace from wind-chill which includes only new parts (not uploaded)? please suggest if any. I have used the recovery tool wherein I could able to retrieve the assembly but no parts within that.

 

thanks,

Dinesh G


Deployment planning checklist

$
0
0

Where do I find the Windchill Deployment Planning Checklist?

Re: Deployment planning checklist

Re: Deployment planning checklist

Publish Additional file DXF under parameter condition

$
0
0

Dear All

 

I need to understand if is possible enable the worker to publish also the DXF format for the Drawing but only  under parameter condition.

My idea is define a boolen parameters on EPM Document like   DXF_Publish   TRUE/FALSE and the make the system

able to publish r  DXF file if the above parameter  was set TRUE.

 

Thanks to everybody  have the solution

 

Beniamino

Re: Windchill 10.2 packaging

$
0
0

*bump*